Modified sine inverters that adjust the energy produced by the solar panel as a square wavelength; direct current turns into alternating current. Modified sine inverters to offer logic power supply; It combines the functions of inverter, solar charger and battery charger. They offer user configurable and easily accessible button functions. Move from unsteady use with high inrush current due to square wave structure. It is more economical, reliable and convenient characteristic than full sine wave inverter. It has the advantage of protecting all loads.
Usage Areas: Solar energy systems, solar street lighting systems, traffic lights, vehicles, ambulances, boats, caravans, computers, printers, scanners, digital cameras, electric fans, energy-saving lamps, electrical household appliances such as hair dryers.
Technicial Specifications
| Rated Output Power | 600 W |
| Maximum Output Power | 1200 W |
| AC Output Voltage | 230 V |
| AC Output Voltage Range | 220 V ~ 240 V |
| AC Regulation | ±%10 |
| Output Frequency | 50 Hz / 60 Hz ±3 |
| No Load Current Draw | ≤ 0,35 A |
| Efficiency | ≥ %90 |
| Output Waveform | Modified sine |
| USB Port | 5 V / 2,1 A (optional) |
| LED Indicator | Green: On (on), Red: Off (off) or malfunction |
| Digital Display | Voltage, power |
| Input Connector | 1 pc. 60 cm cigarette lighter DC cable, 2 battery DC cables |
| Cooling Fan | Load controlled, temperature controlled (optional) |
| DC Input Voltage | 12 V |
| DC Input Voltage Range | 9,5 ~ 16 V |
| Operating Temperature | 0oC ~ +30oC / %100 load, +40oC / %50 load |
| Operating Humidity | %20 ~ %90 RH (non-condensing) |
| Storage Temperature / Humidity | -30oC ~ +70oC / %10 ~ %95 RH |
| Temperature Factor | %10 ~ %90 RH (non-condensing) |
| Insulation Resistance | -20oC ~ +50oC |
| EMI Transmission & Radiation | I/P-O/P: 1000 Ohms / 500 VDC / 25 / %70 RH |
| EMS Immunity | EN55022-B, 72/245/CEE, 95/64/CE with Compliant |
| LVD | EN61000-4-2,3 with Compliant |
| E-mark | EN60950, EN61558-1-2 with Compliant |
| Dimensions | 220 x 135 x 58 mm |
| Weight | 910 gr |
Protection
| Low Voltage Alarm | 9,5 ±0.5 V DC |
| Low Voltage Shutdown (LVS) | 10 ±0.5 V DC |
| Voltage Restoration After | 11,5 ~ 12 V |
| High Voltage | 15 ~ 16 V DC |
| High Temperature | Output voltage shutdown, auto restart |
| Overload | Output voltage shutdown, auto restart |
| Output Short Circuit | Shutdown, auto restart |
| Battery Reverse | Fuse blown |
| Replaceable Fuse | 40 A x 2 |
| Soft Start | Yes, 3 ~ 5 sn |
| There is a Ground Leakage | Yes |