TG-Inverter 015 Carspa 2000 Watt 12 Volt Fully Modified Inverter

Status: In Stock
  • 1.5 years warranty
  • CE, ROHS, CE-LVD/EMC approved
  • Modified sine wave output
  • USB output port
  • Manual control with On/Off switch
  • Compact, lightweight, easy to use
  • Auto restart feature
  • Durability and maximum heat dissipation
  • Loads can be powered directly from the AC outlet
  • Digital display showing battery voltage and charging power
  • 2 LED indicators on the front panel showing the working and fault status
  • Optional remote control

SKU:TG-Inverter 015

Modified sine inverters that adjust the energy produced by the solar panel as a square wavelength; converts direct current to alternating current. Modified sine inverters to offer portable uninterruptible power supply; It combines the functions of inverter, solar charger and battery charger. They offer user configurable and easily accessible button functionality. It is recommended to be used in devices that do not have high inrush current due to its square wave structure. It is more economical, reliable and cost effective than a full sine wave inverter. It has the advantage of operating all resistive loads.

Usage Areas: Solar energy systems, solar street lighting systems, traffic lights, vehicles, ambulances, boats, caravans, computers, printers, scanners, digital cameras, electric fans, energy-saving lamps, electrical household appliances such as hair dryers.

Technicial Specifications

Rated Output Power 2000 W
Maximum Output Power 4000 W (few sec)
AC Output Voltage 230 V
AC Output Voltage Range 220V ~ 240V
AC Regulation ±10%
Output Frequency 50 Hz / 60 Hz ±3
No Load Current Draw ≤ 2 A
Efficiency ≥ 90%
Output Waveform Modified sine
USB Port 5 V / 0.5 A (optional)
LED Indicator Green: On (on), Red: Off (off) or malfunction
Input Connector 2x BVR10 battery cables
Cooling Fan with 30% load or temperature control
DC Input Voltage 12 V
DC Input Voltage Range 9.5 ~ 16 V
Operating Temperature 0oC ~ +30oC / 100% load, +40oC / 50% load
Operating Humidity 20% ~ 90% RH (non-condensing)
Storage Temperature / Humidity -30oC ~ +70oC / 10% ~ 95% RH
Temperature Factor 10% ~ 90% RH (non-condensing)
Insulation Resistance -20oC ~ +50oC
EMI Transmission & Radiation I/P-O/P: 1000 Ohms / 500 VDC / 25 / 70% RH
EMS Immunity Compliant with EN55022-B, 72/245/CEE, 95/64/CE
Compliant with LVD EN61000-4-2.3
Compliant with E-mark EN60950, EN61558-1-2
Dimensions 323 x 229 x 100 mm
Weight 5.85 kg

Protection

Low Voltage Alarm 11 ±0.5 V DC
Low Voltage Shutdown (LVS) 9.5 ±0.5 V DC
Voltage Restoration After LVS 11.5 ~ 12 V DC
High Voltage Shutdown 15 ±0.5 V DC
Over Temperature Output voltage shutdown, auto restart
Overload Output voltage shutdown, auto restart
Output Short Circuit Shutdown, auto restart
Battery Reverse Fuse blown
Replaceable Fuse 30 A x 8, 15 A x 1
Soft Start Yes, 3 ~ 5 sec
There is a Ground Leakage