TG-Inverter 056 Tommatech 1500 Watt 12 Volt Full Sinus Inverter

Status: In Stock
  • 2 years warranty
  • CE, ROHS and E-mark approved
  • Full sine output (THD < 3%)
  • AC output similar to mains output
  • Fully isolated input and output
  • USB output port
  • Ability to start difficult loads with high ripple and high pulse current capacity
  • Smooth start-up of devices with soft current start
  • Auto restart feature
  • LED indicators for power and protections
  • Load-controlled cooling fan (optionally temperature-controlled)

SKU:TG-Inverter 056

The electrical energy produced by the full sine inverter designed as smart systems is transferred from direct current to alternating current. As the inverter balances between direct current and alternating current, technical and hardware problems due to electrical overload are avoided. Full sine inverters are better at tolerating voltage spikes and drops than modified sine inverters. Full sine inverters are more efficient and more costly. Full sine wave can be used in all applications without any problems. With a full sine inverter, the devices heat up less. Many devices that work with a full sine inverter can also work with a modified sine inverter.

Usage Areas: Solar energy systems, solar street lighting systems, traffic lights, vehicles, ambulances, boats, caravans, computers, printers, scanners, digital cameras, electric fans, energy-saving lamps, electrical household appliances such as hair dryers.

 

Technicial Specifications

Rated Output Power 1500 W
Surge Power 3000 W (few seconds)
AC Output Voltage 220 V / 230 V / 240 V
AC Regulation ±5%
Output Frequency 50 Hz / 60 Hz ±3
No Load Current Draw ≤ 1 A
Efficiency > 90%
Output Waveform Full sine (THD < 3%)
USB Port 5 V / 1 A
LED Indicator Green: On (on), Red: Fault
Input Connector 2x BVR4 battery cables
Cooling Fan Load controlled, temperature controlled (optional)
DC Input Voltage 12 V
DC Input Voltage Range 10.5 ~ 15 V
Operating Temperature 0oC ~ +40oC
Operating Humidity 20% ~ 90% RH (non-condensing)
Storage Temperature / Humidity -30oC ~ +70oC / 10% ~ 95% RH
Insulation Resistance I/P-O/P: 1000 Ohms / 500 VDC
EMI Transmission & Radiation Compliant with EN55022-A class
EMS Immunity Compliant with EN61000-3-2.3
Compliant with LVD EN60950-1:2006+A11:2009
Compatible with E-mark E8 10R-05 1512
Dimensions 345 x 230 x 108 mm
Weight 4.7 kg

Protection

Low Voltage Alarm 11 ±0.5 V DC
Low Voltage Shutdown (LVS) 10.5 ±0.5 V DC
Voltage Restoration After LVS 11.8 ~ 12.8 V DC
High Voltage Shutdown 14.8 ±0.5 V DC
Over Temperature Output voltage shutdown, auto restart
Overload Shutdown
Output Short Circuit Output voltage shutdown, auto restart
Battery Reverse Fuse blown
Replaceable Fuse 40 A x 4
Soft Start Yes, 5 ~ 10 sec
There is a Ground Leakage