The electrical energy produced by the full sine inverter designed as smart systems is transferred from direct current to alternating current. As the inverter balances between direct current and alternating current, technical and hardware problems due to electrical overload are avoided. Full sine inverters are better at tolerating voltage spikes and drops than modified sine inverters. Full sine inverters are more efficient and more costly. Full sine wave can be used in all applications without any problems. With a full sine inverter, the devices heat up less. Many devices that work with a full sine inverter can also work with a modified sine inverter.
Usage Areas: Solar energy systems, solar street lighting systems, traffic lights, vehicles, ambulances, boats, caravans, computers, printers, scanners, digital cameras, electric fans, energy-saving lamps, electrical household appliances such as hair dryers.
Modified sine inverters that adjust the energy produced by the solar panel as a square wavelength; direct current turns into alternating current. Modified sine inverters to offer logic power supply; It combines the functions of inverter, solar charger and battery charger. They offer user configurable and easily accessible button functions. Move from unsteady use with high inrush current due to square wave structure. It is more economical, reliable and convenient characteristic than full sine wave inverter. It has the advantage of protecting all loads.
Usage Areas: Solar energy systems, solar street lighting systems, traffic lights, vehicles, ambulances, boats, caravans, computers, printers, scanners, digital cameras, electric fans, energy-saving lamps, electrical household appliances such as hair dryers.
Technicial Specifications
Rated Output Power | 600 W |
Maximum Output Power | 1200 W |
AC Output Voltage | 220 V / 230 V / 240 V |
AC Regulation | ±%5 |
Output Frequency | 50 Hz / 60 Hz ±3 |
No Load Current Draw | ≤ 0,7 A |
Efficiency | ≥ %90 |
Output Waveform | Full sine (THD < 3%) |
USB Port | 5 V / 2,1 A |
LED Indicator | Green: On (on), Red: Off (off) or malfunction |
Input Connector | 2x BVR4 battery cables |
Cooling Fan | Load controlled, temperature controlled (optional) |
DC Input Voltage | 12 V |
DC Input Voltage Range | 10,5 ~ 15 V |
Operating Temperature | 0oC ~ +40oC |
Operating Humidity | %20 ~ %90 RH (non-condensing) |
Storage Temperature / Humidity | -30oC ~ +70oC / %10 ~ %95 RH |
Temperature Factor | %10 ~ %90 RH (non-condensing) |
Insulation Resistance | -20oC ~ +50oC |
EMI Transmission & Radiation | I/P-O/P: 1000 Ohms / 500 VDC / 25 / %70 RH |
EMS Immunity | EN55022-A with Compliant |
LVD | EN60950-1:2006+A11:2009 with Compliant |
E-mark | E8*72/245/EEC, 95/54/EC with Compliant |
Dimensions | 260 x 150 x 77,7 mm |
Weight | 2,1 kg |
Protection
Low Voltage Alarm | 11 ±0,5 V DC |
Low Voltage Shutdown (LVS) | 10 ±0.5 V DC |
Voltage Restoration After | 11,8 ~ 12,8 V |
High Voltage Shutdown | 14,8 ±0,5 V DC |
Extreme Temperature | Output voltage shutdown, auto restart |
Overload | Closing |
Output Short Circuit | Output voltage shutdown, auto restart |
Battery Reverse Pole | When the fuse opens |
Replaceable Fuse | 40 A x 2 |
Soft Start | Yes, 5 ~ 10 sec |
Earthing Leakage | Yes |